{"title":"Spark Killers","description":"\u003cp\u003eA spark killer, also called a spark quencher or RC snubber, is a resistor and capacitor in one small package. It's wired across a relay coil, contactor or solenoid to absorb the voltage spike when the circuit switches off. Without it, contacts arc and pit, and the electrical noise can trip sensors or upset the control.\u003c\/p\u003e\u003ch2\u003eModels we stock\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKEM K3CR-50500, K3CRC-50500, K3CRD-50500, K3CRM-50500:\u003c\/strong\u003e three-phase types for motors and contactors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKEM KCR-10201:\u003c\/strong\u003e single-phase type for relays and solenoids\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eReplacing a spark killer?\u003c\/h2\u003e\u003cp\u003eMatch the model number printed on the part. If it's missing, tell us what it's wired across (motor, contactor, relay or solenoid) and the voltage, and we'll suggest the right one. Call 847-466-5459.\u003c\/p\u003e","products":[{"product_id":"kem-spark-killer-k3crd-50500","title":"KEM Spark Killer K3CR-50500","description":"\u003ch5\u003eProduct Description\u003c\/h5\u003e\n\u003cp\u003eThe circuit inserted between the contact points in order to prevent sparks is called the spark quench circuit, and it's parts are called SPARK KILLER.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003eHigh overload capacity\u003cbr\u003eIt is very effective against surge voltage caused by contact vibration such as chattering.\u003cbr\u003eEffective against external surge voltage.\u003cbr\u003eIt has a very low impedance to high reverse frequencies, so it has the ability to suppress low-level high-frequency noise.\u003cbr\u003eIt is effective to have CR time constant to protect SCR, SSR, etc. and improve dv\/dt.\u003c\/p\u003e\n\u003ch5\u003eProduct Specifications\u003c\/h5\u003e\n\u003ctable style=\"border-collapse:collapse;width:auto;margin:0 0 20px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #d9d9d9;padding:6px 12px;background:#f2f2f7;text-align:center;\"\u003eTHREE PHASE TYPE\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d9d9d9;padding:6px 12px;background:#f2f2f7;text-align:center;\"\u003eCondenser\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d9d9d9;padding:6px 12px;background:#f2f2f7;text-align:center;\"\u003eResistance\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d9d9d9;padding:6px 12px;background:#f2f2f7;text-align:center;\"\u003eVoltage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:6px 12px;text-align:center;\"\u003eStandard Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:6px 12px;text-align:center;\"\u003e 0.47㎌\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:6px 12px;text-align:center;\"\u003e50Ω \u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9;padding:6px 12px;text-align:center;\"\u003e 110 \/220V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eExternal Dimensions\u003c\/h5\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0962\/6107\/9359\/files\/K3CR-50500-Dimension.jpg?v=1792789248\" alt=\"K3CR-50500\" width=\"1366\" height=\"659\" style=\"width:1366px;max-width:100%;height:auto;display:block;\" loading=\"lazy\"\u003e\u003c\/p\u003e","brand":"KEM","offers":[{"title":"Default Title","offer_id":51707849507135,"sku":"706K3R50500","price":60.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0962\/6107\/9359\/files\/k3cr-50500-web_1.jpg?v=1768214436"},{"product_id":"kem-spark-killer-k3crd-50500-584","title":"KEM Spark Killer K3CRD-50500","description":"\u003cp style=\"text-align: center\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\"\u003eProduct Description\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003eThe circuit inserted between the contact points in order to prevent sparks is called the spark quench circuit, and it's parts are called SPARK KILLER.\u003c\/span\u003e\u003cspan style=\"font-size:\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size:\"\u003e\u003cspan style=\"font-size:\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003eHigh overload capacity\u003cbr\u003eIt is very effective against surge voltage caused by contact vibration such as chattering.\u003cbr\u003eEffective against external surge voltage.\u003cbr\u003eIt has a very low impedance to high reverse frequencies, so it has the ability to suppress low-level high-frequency noise.\u003cbr\u003eIt is effective to have CR time constant to protect SCR, SSR, etc. and improve dv\/dt.\u003c\/span\u003e\u003cspan style=\"font-size:\"\u003e\u003c\/span\u003e\u003cspan style=\"font-size:\"\u003e\u003c\/span\u003e\u003cspan style=\"font-size:\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\"\u003eProduct Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" style=\"width:\" collapse height=\"382\" border-collapse:=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center width: height:\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\"\u003eTHREE PHASE TYPE\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center width: height:\"\u003e\u003cspan style=\"font-size:\"\u003eStandard Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width:\" text-align: center colspan=\"2\" rowspan=\"4\"\u003e\u003cspan style=\"font-size:\"\u003e\u003cimg alt=\"KRCD-50500\" src=\"https:\/\/www.industrynestparts.com\/media\/wysiwyg\/KRCD-50500.PNG\" width=\"100%\" height=\"100%\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center width: height:\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\"\u003eCondenser\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center width: height:\"\u003e\u003cspan style=\"font-size:\"\u003e 0.47㎌\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center width: height:\"\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center width: height:\"\u003e\u003cspan style=\"font-size:\"\u003e50Ω \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center width: height:\"\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center width: height:\"\u003e\u003cspan style=\"font-size:\"\u003e110 \/220V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003c\/p\u003e","brand":"KEM","offers":[{"title":"Default Title","offer_id":51707933229375,"sku":"K3CRD50500","price":60.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0962\/6107\/9359\/files\/k3crd_50500_web.jpg?v=1768219814"},{"product_id":"kem-spark-killer-k3crc-50500-585","title":"KEM Spark Killer K3CRC-50500","description":"\u003cp style=\"text-align: center\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\"\u003eProduct Description\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003eThe circuit inserted between the contact points in order to prevent sparks is called the spark quench circuit, and it's parts are called SPARK KILLER.\u003c\/span\u003e\u003cspan style=\"font-size:\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size:\"\u003e\u003cspan style=\"font-size:\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003eHigh overload capacity\u003cbr\u003eIt is very effective against surge voltage caused by contact vibration such as chattering.\u003cbr\u003eEffective against external surge voltage.\u003cbr\u003eIt has a very low impedance to high reverse frequencies, so it has the ability to suppress low-level high-frequency noise.\u003cbr\u003eIt is effective to have CR time constant to protect SCR, SSR, etc. and improve dv\/dt.\u003c\/span\u003e\u003cspan style=\"font-size:\"\u003e\u003c\/span\u003e\u003cspan style=\"font-size:\"\u003e\u003c\/span\u003e\u003cspan style=\"font-size:\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\"\u003eProduct Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" style=\"width:\" collapse height=\"382\" border-collapse:=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center width: height:\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\"\u003eTHREE PHASE TYPE\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center width: height:\"\u003e\u003cspan style=\"font-size:\"\u003eChannel Wire type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width:\" text-align: center colspan=\"2\" rowspan=\"4\"\u003e\u003cimg alt=\"K3CRC-50500\" src=\"https:\/\/www.industrynestparts.com\/media\/wysiwyg\/K3CRC-50500.PNG\" width=\"100%\" height=\"100%\" style=\"float: left\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center width: height:\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\"\u003eCondenser\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center width: height:\"\u003e\u003cspan style=\"font-size:\"\u003e 0.47㎌\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center width: height:\"\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center width: height:\"\u003e\u003cspan style=\"font-size:\"\u003e50Ω \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center width: height:\"\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center width: height:\"\u003e\u003cspan style=\"font-size:\"\u003e110 \/220V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003c\/p\u003e","brand":"KEM","offers":[{"title":"Default Title","offer_id":51707933622591,"sku":"K3CRC50500","price":60.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0962\/6107\/9359\/files\/k3crc_50500_web.jpg?v=1768219844"},{"product_id":"kem-spark-killer-kcr-10201","title":"KEM Spark Killer KCR-10201","description":"\u003cp style=\"text-align: center\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\"\u003eProduct Description\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003eThe circuit inserted between the contact points in order to prevent sparks is called the spark quench circuit, and it's parts are called SPARK KILLER.\u003c\/span\u003e\u003cspan style=\"font-size:\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size:\"\u003e\u003cspan style=\"font-size:\"\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003eHigh overload capacity\u003cbr\u003eIt is very effective against surge voltage caused by contact vibration such as chattering.\u003cbr\u003eEffective against external surge voltage.\u003cbr\u003eIt has a very low impedance to high reverse frequencies, so it has the ability to suppress low-level high-frequency noise.\u003cbr\u003eIt is effective to have CR time constant to protect SCR, SSR, etc. and improve dv\/dt.\u003c\/span\u003e\u003cspan style=\"font-size:\"\u003e\u003c\/span\u003e\u003cspan style=\"font-size:\"\u003e\u003c\/span\u003e\u003cspan style=\"font-size:\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\"\u003eProduct Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" style=\"width:\" collapse height=\"382\" border-collapse:=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center width: height:\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\"\u003eSINGLE PHASE TYPE\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center width: height:\"\u003e\u003cspan style=\"font-size:\"\u003eStandard Wire Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width:\" text-align: center colspan=\"2\" rowspan=\"4\"\u003e\u003cimg alt=\"KCR-10201\" src=\"https:\/\/www.industrynestparts.com\/media\/wysiwyg\/KCR-10201.PNG\" width=\"100%\" height=\"100%\" style=\"float: left\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center width: height:\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\"\u003eCondenser\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center width: height:\"\u003e\u003cspan style=\"font-size:\"\u003e 0.1㎌\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center width: height:\"\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center width: height:\"\u003e\u003cspan style=\"font-size:\"\u003e200Ω \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center width: height:\"\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center width: height:\"\u003e\u003cspan style=\"font-size:\"\u003e110 \/220V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003c\/p\u003e","brand":"KEM","offers":[{"title":"Default Title","offer_id":51707933917503,"sku":"KCR10201","price":40.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0962\/6107\/9359\/files\/kcr_10201_web.jpg?v=1768219873"},{"product_id":"kem-spark-killer-k3crm-50500","title":"KEM Spark Killer K3CRM-50500","description":"\u003cp style=\"text-align: center\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\"\u003eProduct Description\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"section_layout\"\u003e\n\u003cli class=\"ly_full\" style=\"list-style-type: none\"\u003e\n\u003cul class=\"section_items\"\u003e\n\u003cli class=\"item_box\"\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:\"\u003eIt's often the case to sue the electronic machine parts when transforming the electrical system into the machinery system of a device.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:\"\u003eln this case, the inductance of the coil creates the pulse counter voltage of high energy.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:\"\u003eLet's suppose the case in which the contact point  of circuit switches on and off.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:\"\u003elf there's voltage involved in the contact point, there is current when the contact point is closed.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:\"\u003eWhen it's open, the counter electromotive force of inductance creates voltage along with sparks, glows and ARC.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:\"\u003eln addition, the vibration of high frequency will potentially interfere with the electronic circuit.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:\"\u003eDue to the sparks, the contact points get to be exhausted.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:\"\u003etransformed or desposited, the increased oxidative contact resistance on the surface and contact defects will reduce the life.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"font-size:\"\u003eThe circuit inserted between the contact points in order to prevent sparks is called the spark quench circuit, and it's parts are called \u003c\/span\u003e\u003cspan style=\"font-size:\"\u003eSPARK KILLER(SPARK QUENCHER).\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"item_box\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\"\u003eCharacteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003e1. lt has a great durability of overload.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003e2. The effects of chattering and contact point vlbration on the surge voltage are huge.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003e3. It's effects on exterior surge vltage are great.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003e4. Since it's impedavce against the high counter frequency is very small, it can control the high frequency noise of low levels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003e5. lt protects SCR and SSR and lmproves dv\/dt, contributing to having the CR time constant.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"item_box\"\u003e\u003cspan style=\"font-size:\"\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"item_box\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\"\u003eUse\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003e- Various electric circults for opening and closing\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003e- Machine tools\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003e- Automatic machines\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"item_box\"\u003e\u003cspan style=\"font-size:\"\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"item_box\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\"\u003ePrecautions for use\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003eWhen high frequency power is input to the spark killer(Spark quencher) Due to the high heat from the resistor by conduction phenomenon of the capacitor in the \u003c\/span\u003e\u003cspan style=\"font-size:\"\u003eCR circuit Temperature increase of the spark killer(Spark quencher) in use, so a spark can occur or more or less so that the killer 5℃ We should use and inspection \u003c\/span\u003e\u003cspan style=\"font-size:\"\u003eis essential.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\"\u003eProduct Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" style=\"border-collapse: collapse width:=\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: text-align: center height:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\"\u003eTHREE PHASE TYPE\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: text-align: center height:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\"\u003eCondenser\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: text-align: center height:\"\u003e\u003cspan style=\"font-size:\"\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: text-align: center height:\"\u003e\u003cspan style=\"font-size:\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: text-align: center height:\"\u003e\u003cspan style=\"font-size:\"\u003eChannel internal magnet type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: text-align: center height:\"\u003e\u003cspan style=\"font-size:\"\u003e0.47㎌\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: text-align: center height:\"\u003e\u003cspan style=\"font-size:\"\u003e50Ω \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: text-align: center height:\"\u003e\u003cspan style=\"font-size:\"\u003e110 \/220V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003e※ Operating Temperature : -25~ +70℃\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"section_items\"\u003e\n\u003cli class=\"item_box\"\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003e- R(Ω) ± 20%\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003e- C(㎌) ± 20%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cul class=\"section_layout\"\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\"\u003eProduct Drawing\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"K3CRM-50500\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0962\/6107\/9359\/files\/K3CRM-50500.png?v=1792789234\" width=\"400\" height=\"\" style=\"display: block margin-left: auto margin-right:\"\u003e\u003c\/p\u003e\n\u003cul class=\"section_layout\"\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\"\u003eUse example\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0962\/6107\/9359\/files\/Spark_Killer_use_example.jpg?v=1792789441\" alt=\"\" width=\"\" height=\"400\" style=\"display: block margin-left: auto margin-right:\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"KEM","offers":[{"title":"Default Title","offer_id":51707934605631,"sku":"K3CRM50500","price":60.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0962\/6107\/9359\/files\/k3crm_50500_web.jpg?v=1768219904"}],"url":"https:\/\/www.industrynestparts.com\/collections\/spark-killers.oembed","provider":"IndustryNest","version":"1.0","type":"link"}