{"product_id":"aryung-coolant-pump-achk-10-60-6-50hz","title":"Aryung Coolant Pump ACHK 10-60\/6 (50 Hz)","description":"\u003cp\u003eThe Aryung ACHK 10-60\/6 is a 4.0 kW compact stainless steel multistage immersion pump for machine tool coolant systems, with 6 impeller stages in 6 chambers. The ACHK series is a medium-pressure multistage centrifugal pump with a compact build for machines where space in or above the tank is tight. Wetted parts are stainless steel and the mechanical seal uses FKM, so it holds up to heat and long run times. Typical uses: CNC lathes, machining centers, grinders, parts washers and filtration systems.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e50 Hz build.\u003c\/strong\u003e This listing is for 50 Hz power. Most US plants run on 60 Hz, and the 60 Hz version of a given model can use a different motor and stage count. For 60 Hz, see the ACHK 10 60 Hz listings or ask us for the closest match.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eBuilt to order:\u003c\/strong\u003e this model is made by Aryung in Korea and ships in about 30 days. Request a quote for price and lead time, or call 847-466-5459.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSize\u003c\/th\u003e\n\u003ctd\u003eACHK 10 (standard flow 10 m³\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChambers\u003c\/th\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpeller stages\u003c\/th\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor output\u003c\/th\u003e\n\u003ctd\u003e4.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e200 \/ 380 \/ 415 V, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical seal\u003c\/th\u003e\n\u003ctd\u003eSiC\/carbon (SC), SiC\/TC (ST) or TC\/TC (TT), FKM (Viton) elastomers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeal limits\u003c\/th\u003e\n\u003ctd\u003e2.5 MPa max, 0 to 120°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eUse\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFluid must be clean and low viscosity, free of solid particles, abrasive sludge and fibers, and not explosive.\u003c\/li\u003e\n\u003cli\u003eIf the fluid is heavier or thicker than water-soluble coolant, the motor may need to be upsized.\u003c\/li\u003e\n\u003cli\u003eImmersion depth can be extended with empty chambers. More empty chambers lowers the pressure.\u003c\/li\u003e\n\u003cli\u003eFit a baffle between the discharge and suction sides of the tank so returning chips and air are not pulled straight back in.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDimensions\u003c\/h2\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0962\/6107\/9359\/files\/aryung-achk-10-dimensions-1.jpg\" alt=\"ACHK 10 dimension drawing\" width=\"100%\"\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eA\u003c\/th\u003e\n\u003cth\u003eB\u003c\/th\u003e\n\u003cth\u003eC\u003c\/th\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003cth\u003eE\u003c\/th\u003e\n\u003cth\u003eF\u003c\/th\u003e\n\u003cth\u003eG\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACHK 10-60\/6\u003c\/td\u003e\n\u003ctd\u003e594\u003c\/td\u003e\n\u003ctd\u003e261\u003c\/td\u003e\n\u003ctd\u003e333\u003c\/td\u003e\n\u003ctd\u003e183\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003ctd\u003e234\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eDimensions in mm.\u003c\/p\u003e\u003ch2\u003ePerformance curve, 50 Hz\u003c\/h2\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0962\/6107\/9359\/files\/aryung-achk-10-50hz-performance-curve.jpg\" alt=\"Aryung ACHK 10 performance curve, 50 Hz\" width=\"100%\"\u003e\u003c\/p\u003e\u003cp\u003eRead the curve for 6 stages. Curves are based on ISO VG 2 (2 cSt) fluid at 20°C.\u003c\/p\u003e\u003ch2\u003eModel number guide\u003c\/h2\u003e\u003cp\u003eACHK = series, 10 = standard flow (10 m³\/h), 60 = number of chambers x 10 (6 chambers), 6 = number of impeller stages. Codes follow for the seal material (SC, ST or TT) and voltage (2\/2 = 200\/220 V, 2\/3 = 220\/380 V, 4\/4 = 415\/440 V).\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/cdn\/shop\/files\/aryung-coolant-pump-catalog-2026.pdf#page=84\"\u003eAryung Coolant Pump Catalog 2026 (PDF), ACHK series\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/catalogs-manuals-a-ryung\"\u003eAll A-Ryung catalogs and 3D models\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eSpecifications from Aryung's 2026 coolant pump catalog. Confirm voltage, outlet and dimensions with us before ordering.\u003c\/em\u003e\u003c\/p\u003e","brand":"Aryung","offers":[{"title":"Default Title","offer_id":67892510949695,"sku":"ACHK1060650Hz","price":1000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0962\/6107\/9359\/files\/aryung-achk-multistage-coolant-pump.png?v=1793247615","url":"https:\/\/www.industrynestparts.com\/products\/aryung-coolant-pump-achk-10-60-6-50hz","provider":"IndustryNest","version":"1.0","type":"link"}