{"product_id":"dahasystemspressureswitch10010-3","title":"DAHA Systems SH Pressure switch","description":"\u003cp style=\"text-align: center\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\"\u003eProduct Description\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-size:\"\u003e\u003cstrong\u003eSafety Instruction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTo use the product safely, always follow the Instructions below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou must follow the instructions for use.\u003c\/p\u003e\n\u003cp\u003eYou must be familiar with the usage regulations and legal matters of each country before using it\u003c\/p\u003e\n\u003cp\u003eDo not use beyond the specifications of the product. (pressure, force, temperature, other environment, etc.)\u003c\/p\u003e\n\u003cp\u003eBefore using the product, be sure to consider the surrounding environment (temperature, humidity, dust, etc.)\u003c\/p\u003e\n\u003cp\u003eDo not use in places where there is a lot of vibration, shock, or adverse effects on the operation of the sensor.\u003c\/p\u003e\n\u003cp\u003eThe product must not be modified and used.\u003c\/p\u003e\n\u003cp\u003eRemove all packing materials used during delivery and use them (laps, boxes, etc.)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eWhen discarding, separate reusable parts and dispose of them.\u003c\/p\u003e\n\u003cp\u003eDo not pull hard on the cable\u003c\/p\u003e\n\u003cp\u003eInstall the pressure sensor after removing the dust remaining in the pressure line and the pressure medium that can cause overpressure when tightening\u003c\/p\u003e\n\u003cp\u003eWhen installing, be sure to tighten it using the spanner seat of the female screw part.\u003c\/p\u003e\n\u003cp\u003eDo not do wiring work while electricity is running.\u003c\/p\u003e\n\u003cp\u003eDo not repeatedly bend the cable, pull it, or apply force by placing heavy objects on top of it..\u003c\/p\u003e\n\u003cp\u003eThe product must not be modified and used\u003c\/p\u003e\n\u003cp\u003eDo not use near places where strong high- frequency noise is generated\u003c\/p\u003e\n\u003cp\u003eDo not use in locations with surge sources\u003c\/p\u003e\n\u003cp\u003ePerform maintenance and inspection after turning off the supply power.\u003c\/p\u003e\n\u003cp\u003ePlease perform maintenance and inspection regularly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\"\u003eProduct Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-size:\"\u003e\u003cstrong\u003eDAHA Systems SH Pressure sensor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-size:\"\u003e\u003cstrong\u003eSpecification \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"height:\" border=\"1\" width:=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"147\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd width=\"147\" style=\"text-align: center\"\u003e15DVC\u003c\/td\u003e\n\u003ctd width=\"147\" style=\"text-align: center\"\u003e24VDC\u003c\/td\u003e\n\u003ctd width=\"147\" style=\"text-align: center\"\u003e30DVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"text-align: center\"\u003e13VDC(-2V)\u003c\/td\u003e\n\u003ctd style=\"text-align: center\"\u003e22VDC(-2V)\u003c\/td\u003e\n\u003ctd style=\"text-align: center\"\u003e28DVC(-2V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"text-align: center\"\u003e250Ma (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"text-align: center\"\u003eIntemal Software type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Drop\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"text-align: center\"\u003e2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eEMI\/EMS Protection circuit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-size:\"\u003e\u003cstrong\u003eEnviromental Condition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable width=\"100%\" style=\"height:\" border=\"1\" width:=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height:\"\u003e\n\u003ctd colspan=\"2\" style=\"height: width: text-align: center\"\u003eOperating Pressure Range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: width: text-align: center\"\u003e1~100Bar, 1~10Bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height:\"\u003e\n\u003ctd colspan=\"2\" style=\"height: width: text-align: center\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: width: text-align: center\"\u003e0.5% FS(Typ)@25°C  0.3% FS(Max)@30°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height:\"\u003e\n\u003ctd colspan=\"2\" style=\"height: width: text-align: center\"\u003eLinear Repeatability\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: width: text-align: center\"\u003e0.10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height:\"\u003e\n\u003ctd colspan=\"2\" style=\"height: width: text-align: center\"\u003eOverPressure\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: width: text-align: center\"\u003e200%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height:\"\u003e\n\u003ctd colspan=\"2\" style=\"height: width: text-align: center\"\u003eHysteresys\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: width: text-align: center\"\u003e1% less than\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height:\"\u003e\n\u003ctd colspan=\"2\" style=\"height: width: text-align: center\"\u003eSwitching Cycle\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: width: text-align: center\"\u003e100 million times\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height:\"\u003e\n\u003ctd colspan=\"2\" style=\"height: width: text-align: center\"\u003eLong Term Stability\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: width: text-align: center\"\u003e0.15% FS\/Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height:\"\u003e\n\u003ctd colspan=\"2\" style=\"height: width: text-align: center\"\u003eZero Offset\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: width: text-align: center\"\u003e0.2mV\/V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height:\"\u003e\n\u003ctd colspan=\"2\" style=\"height: width: text-align: center\"\u003eCompensated Temp Range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: width: text-align: center\"\u003e-25°C ~ +110°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height:\"\u003e\n\u003ctd colspan=\"2\" style=\"height: width: text-align: center\"\u003eOperating Temp Range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: width: text-align: center\"\u003e-40°C ~ +125°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height:\"\u003e\n\u003ctd colspan=\"2\" style=\"height: width: text-align: center\"\u003eStorageTemp Range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: width: text-align: center\"\u003e-40°C ~ +130°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\n\u003cstrong\u003ePrecautions when using with external devices\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eWhen using an external relay together with the SH Electrical Pressure Switch, the output signal and the COM (GRD) terminal are used because the SH Electrical Pressure Switch is a voltage output type\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.industrynestparts.com\/media\/.renditions\/wysiwyg\/YHB\/SH_Electrical_pressure_Switch.GIF\" alt=\"SH\" electrical pressure switch\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u0026lt; Example of correct usage\u0026gt;\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/www.industrynestparts.com\/media\/.renditions\/wysiwyg\/YHB\/SH_Electrical_pressure_Switch_1.GIF\" alt=\"SH\" electrical pressure switch\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"DAHA Systems","offers":[{"title":"A : 1~100 Bar \/ 1: PF1\/8","offer_id":51708831203647,"sku":"DahaSHSwitch-A1","price":450.0,"currency_code":"USD","in_stock":true},{"title":"A : 1~100 Bar \/ 2: PT1\/4","offer_id":51708831236415,"sku":"DahaSHSwitch-A2","price":450.0,"currency_code":"USD","in_stock":true},{"title":"B : 1 ~10 Bar \/ 1: PF1\/8","offer_id":51708831269183,"sku":"DahaSHSwitch-B1","price":450.0,"currency_code":"USD","in_stock":true},{"title":"B : 1 ~10 Bar \/ 2: PT1\/4","offer_id":51708831301951,"sku":"DahaSHSwitch-B2","price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0962\/6107\/9359\/files\/sh_sensor.jpg?v=1768240845","url":"https:\/\/www.industrynestparts.com\/products\/dahasystemspressureswitch10010-3","provider":"IndustryNest","version":"1.0","type":"link"}