A flashing H means the chiller is not cooling. The oil temperature is above the upper limit.
What to check
- Warm air from the top of the chiller. If the air coming out is warm but the oil is not being cooled, the refrigerant has most likely leaked out.
- Airflow first. Rule out a clogged air filter or condenser and a stopped fan. See Alarm 02.
Refrigerant leaks need a technician
Finding and repairing a leak, and recharging refrigerant (R407C or R410A depending on model), must be done by an EPA 608 certified refrigeration technician. Call us. We can quote the repair parts or a replacement chiller.
Repair parts
Kwangrim recommends replacing the dryer whenever the compressor is replaced.
- Compressor CL0302002 (Doosan R90695C-11)
- Compressor CL0302001 (Doosan 400206-00319-03)
- Compressor CL0702001 (Doosan 400206-00193A-05)
- Compressor CL1102001 (Doosan 400206-00328-04)
- Compressor CL1502001 (Doosan 400206-00484-07)
- Compressor CL2202001 (Doosan 400206-00202-09)
- Dryer CL00D02, 31.75 mm
- Dryer CL00D01, 50.8 mm (Doosan 400206-00202-10)
Still showing the alarm?
Call 847-466-5459 or email admin@industrynestparts.com with the alarm code, the chiller model and serial number from the nameplate, your machine model, and the supply voltage and frequency. If you can, press the PARA key and send us the parameter readings shown on the display. That lets us find the cause and the right part on the first call.